Options<br />

ESIB<br />

Option FSE-B16 – Ethernet Adapter<br />

With the option Ethernet Adapter FSE-B16, the device can be connected to an Ethernet-LAN (local area<br />

network). It is possible to transmit data via the network and to use the network printer. The adapter<br />

operates with a 10 MHz Ethernet in line with standards IEEE 802.3 10Base2 (Thin Ethernet,<br />

CheaperNet, BNC-Net) (B16 model 03) or 10Base5 (Thick Ethernet) (B16 model 02).<br />

Hardware Installation<br />

Caution:<br />

Prior to installation contact the network administrator, especially in case of complex<br />

LAN installations since mistakes in cabling might have influence the whole network.<br />

If the adapter is installed at the factory, it is preconfigured. In case of retrofitting, refer to the installation<br />

instructions. The hardware settings must not be modified since the functions of the device could<br />

otherwise be impaired.<br />

The following parameters are factory-set:<br />

I/O Addr. 300, IRQ 5, MEM D0000<br />

The connection with the network depends on the connectors used in the network.<br />

BNC (Thin Ethernet, CheaperNet; FSE-B16 Var. 03)<br />

Connection<br />

Network traffic<br />

The device is looped into the LAN segment via rear-panel 2 BNC<br />

connectors.<br />

If a cable is not connected to one of the BNC connectors, this BNC<br />

connector has to be terminated with 50 Ohm. BNC T connectors<br />

must not be used.<br />

Note that the network traffic is disturbed if a segment is interrupted.<br />

Requirements<br />

Thin Ethernet segment requirements have to be complied with:<br />

- maximum segment length of 185 m<br />

- minimum distance between the connectors of 0.5 m<br />

- maximum of 30 connectors per segment.<br />

If components that comply with enhanced requirements are<br />

exclusively used (Ethernet Adapter FSE-B16 complies with the<br />

enhanced requirements):<br />

- maximum length of segment of 300 m<br />

- maximum number of connectors of 100<br />

With repeaters used:<br />

- maximum total length of the network of 900 m containing a<br />

- maximum of 3 segments<br />

- maximum of two repeaters between two connectors<br />

1088.7531.12 1.42 E-3