ESIB<br />

Receiver - Display and Limit Lines<br />

NAME<br />

The NAME softkey activates the entry of characteristics in the table heading.<br />

Name - Enter name<br />

A maximum of 8 characters are permitted for each name. All names must be<br />

compatible with the MS-DOS conventions for file names. The instrument<br />

automatically stores all limit lines with the .LIM extension.<br />

IEC\IEEE bus command<br />

:CALCulate:LIMit:NAME <br />

Domain - Indication of frequency domain<br />

In the receiver mode, only frequency domain is used.<br />

EE bus command<br />

:CALCulate:LIMit:DOMain FREQuency<br />

X-Axis - Indication of interpolation<br />

Linear or logarithmic interpolation can be carried out between the frequency<br />

reference points of the table. Selection is via the ENTER key which is toggled<br />

between LIN and LOG (toggle function).<br />

EC-Bus-Befehl<br />

:CALCulate:LIMit:CONTrol:SPACing LIN | LOG<br />

:CALCulate:LIMit:UPPer:SPACing LIN | LOG<br />

:CALCulate:LIMit:LOWer:SPACing LIN | LOG<br />

Scaling - Indication of scaling<br />

In the receiver mode, absolute scaling is used.<br />

X-Scaling ABSOLUTE The frequencies are interpreted as absolute<br />

physical units.<br />

Y-Scaling ABSOLUTE The limit values are absolute levels or voltages.<br />

IEC\IEEE bus command<br />

:CALCulate:LIMit:MODE ABSolute<br />

Unit - Selecting the vertical scale units for the limit line<br />

Units are selected in a selection box. The default setting is dBm.<br />

IEC\IEEE bus command :CALCulate:LIMit:UNIT<br />

DB| DBM| PCT |DBUV| DBMW | DBUA | DBPW|<br />

DBPT | WATT| VOLT | AMPere | DBUV_MHZ |<br />

DBMV_MHZ| DBUA_MHZ | DBUV_M | DBUV_MMHZ<br />

| DBUA_M | DBUA_MMHZ<br />

Limit - Selecting the upper/lower limit<br />

A limit line can be defined as either an upper or lower limit.<br />

IEC\IEEE bus command --<br />

(defined by the key words :UPPer or :LOWer)<br />

Comment - Enter comments<br />

Comments are user selectable, but may not exceed 40 characters in length.<br />

IEC\IEEE bus command<br />

:CALCulate:LIMit:COMMent ’string’<br />

1088.7531.12 4.141 E-15