SENSe Subsystem<br />

ESIB<br />

:[SENSe:]CORRection:TSET:UNIT ’DB’ | ’DBM’ | ’DBUV’ | ’DBUV/M’ | ’DBUA’ | ’DBUA/M’’ |<br />

’DBPW’ | ’DBPT <br />

This command defines the unit of the selected transducer sets. When assigning transducer factors<br />

to the set, only factors which are compatible to the selected unit, i. e. factors with the same unit or the<br />

unit dB, are allowed.<br />

Example: ":CORR:TSET:UNIT ’DBUV’"<br />

Features: *RST value: ’DB’<br />

SCPI: device-specific<br />

Modes:<br />

R, A<br />

Prior to this command, the command SENS:CORR:TSET:SEL must be sent.<br />

:[SENSe:]CORRection:TSET:BREak ON | OFF<br />

This command defines if the sweep is to be stopped on changeover from range to another.<br />

Example: ":CORR:TSET:BRE ON"<br />

Features: *RST value: OFF<br />

SCPI: device-specific<br />

Modes:<br />

R, A<br />

Prior to the above command, the command SENS:CORR:TSET:SEL must be sent.<br />

:[SENSe:]CORRection:TSET:COMMent <br />

This command defines the comment for the selected transducer set.<br />

Example: ":CORR:TSET:COMM ’SET FOR ANTENNA’"<br />

Features: *RST value ’’ (empty comment)<br />

SCPI: device specific<br />

Modes:<br />

R, A<br />

Prior to this command, the command SENS:CORR:TSET:SEL must be sent.<br />

:[SENSe:]CORRection:TSET:RANGe ,,..<br />

This command defines a partial range of the selected transducer set. The partial range is determined<br />

by its start and stop frequencies plus a list of names of the assigned transducer factors. The ranges<br />

1 to 10 must be sent in ascending order.<br />

Parameter: ,::= start frequency, stop frequency of the range<br />

...::= list of names for the assigned transducer factors.<br />

The individual names must be characterized by single<br />

quotation marks (’) and separated by commas.<br />

Example: ":CORR:TRAN:TSET:RANG 1MHZ,2MHZ,’FACTOR1,’FACTOR2’"<br />

Features: *RST value: -<br />

SCPI: device-specific<br />

Modes:<br />

R, A<br />

Prior to this command, the command SENS:CORR:TSET:SEL must be sent.<br />