ESIB<br />

Analyzer - Main Markers<br />

CP/ACP<br />

ABS REL<br />

The CP/ACP ABS/REL softkey (Channel Power/Adjacent Channel Power<br />

Absolute /Relative) switches between an absolute and relative display of the<br />

power measured in the channel or adjacent channel.<br />

Channel power measurement<br />

CP ABS The absolute value of the power is displayed in the unit of the<br />

Y axis, eg in dBm, dBV.<br />

CP REL The power of a freely selected channel is measured. This<br />

power is set in relation to the power of a reference channel.<br />

The reference channel power is selected beforehand using<br />

the SET CP REFERENCE softkey, ie:<br />

1. Declare the power in the currently measured channel as<br />

the reference value using the SET CP REFERENCE<br />

softkey.<br />

2. Set the channel of interest by changing the channel<br />

frequency (ESIB center frequency).<br />

In case of linear scale of the Y axis the relative power<br />

(CP/CP ref ) of the new channel is displayed in addition to the<br />

reference channel. In case of dB scale, the logarithmic ratio<br />

20×log (CP/CP ref ) is displayed.<br />

Therefore, the relative channel power measurement can also<br />

be used for universal adjacent channel power measurements.<br />

Example:<br />

Measurement of the 1597-QCDMA adjacent channel power.<br />

The useful channel and the adjacent channels have different<br />

bandwidths (1.23 MHz or 30 kHz).<br />

Adjacent channel power measurement<br />

The power of the adjacent channels is measured. The<br />

reference value is the power of the useful channels (see<br />

measurement of the adjacent channel power). The useful<br />

channel is marked by two vertical lines that are labelled with<br />

C0.<br />

ACP ABS The powers of the useful channel and of the adjacent<br />

channels are displayed as absolute values in the unit of the Y<br />

axis.<br />

ACP REL The logarithmic ratio 20×log (CP/CP 0 ) of the powers of the<br />

adjacent channels to the useful channel is displayed<br />

The softkey is not available for OCCUPIED PWR BANDWIDTH, C/N and<br />

C/N0<br />

IEC/IEEE-bus command<br />

:[SENSe:]POWer:ACHannel:MODE ABS|REL<br />

SET CP<br />

REFERENCE<br />

The SET CP REFERENCE softkey sets the reference value to the currently<br />

measured channel power for an activated CHANNEL POWER power<br />

measurement,.<br />

IEC/IEEE-bus command<br />

:[SENSe:]POWer:ACHannel:REF:AUTO ONCE<br />

1088.7531.12 4.189 E-15