ESIB<br />

Analyzer - Main Markers<br />

ACP<br />

STANDARD<br />

The ACP STANDARD softkey activates the selection of a digital mobile-radio<br />

standard. The parameters for the adjacent channel power measurement are<br />

set according to the regulations of the selected standard.<br />

ACP STANDARD<br />

NONE<br />

NADC<br />

TETRA<br />

PDC<br />

PHS<br />

CDPD<br />

CDMA800 FWD<br />

CDMA800 REV<br />

CDMA1900 FWD<br />

CDMA1900 REV<br />

W-CDMA FWD<br />

W-CDMA REV<br />

W-CDMA 3GPP FWD<br />

W-CDMA 3GPP REV<br />

CDMA2000 MC<br />

CDMA2000 DS<br />

CDMA ONE 800 FWD<br />

CDMA ONE 800 REV<br />

CDMA ONE 1900 FWD<br />

CDMA ONE 1900 REV<br />

The following standards can be selected:<br />

NADC (IS-54 B)<br />

TETRA<br />

PDC (RCR STD-27)<br />

PHS (RCR STD-28)<br />

CDPD<br />

CDMA800FWD<br />

CDMA800REV<br />

CDMA1900REV<br />

CDMA1900FWD<br />

W-CDMA FWD<br />

W-CDMA REV<br />

W-CDMA 3GPP FWD<br />

W-CDMA 3GPP REV<br />

CDMA2000 Multi Carrier<br />

CDMA2000 Direct Sequence<br />

CDMA ONE 800 FWD<br />

CDMA ONE 800 REV<br />

CDMA ONE 1900 REV<br />

CDMA ONE 1900 FWD<br />

If the full dynamic range of the analyzer is to be utilized for the W-CDMA<br />

measurement (for a power measurement in this standard), the RF attenuation<br />

has to be set to 0 dB.<br />

However this is not done automatically to avoid damaging the analyzer input.<br />

Instead, a window displaying the following note is shown if one of the W-<br />

CDMA standards is selected: ’Attention: For higher dynamic range use RF<br />

ATTEN MANUAL=0dB.<br />

The following parameters change according to the standard selected:<br />

• channel spacing<br />

• channel bandwidth<br />

• modulation filter<br />

• resolution bandwidth<br />

• video bandwidth<br />

• detector<br />

Trace Maths and Trace Averaging are switched off.<br />

The reference level is not changed when a standard is selected. It has to be<br />

set for an optimum dynamic range so that the signal maximum is in the<br />

vicinity of the reference level.<br />

The basic setting ACP STANDARD NONE.<br />

IEC/IEEE-bus command<br />

:CALCulate:MARKer:FUNCtion:POWer:PRESet<br />

NONE |NADC |TETRA |PDC |PHS |CDPD |F8CDma |R8CDma<br />

|F19Cdma |R19Cdma |FWCDma | RWCDma |FW3Gppcdma<br />

|RW3Gppcdma |M2CDma |D2CDma |FO8Cdma |RO8Cdma |FO19cdma<br />