Traces - Analyzer<br />

ESIB<br />

Trace Selection and Setup –TRACE Key Group<br />

The ESIB can display up to four separate traces at a time on a screen. A trace has of a maximum of<br />

500 pixels along the horizontal axis (frequency or time). If more measured values than pixels are<br />

available, several measurement values are assigned to one pixel.<br />

The traces are selected using keys 1 to 4 of the TRACES key group. When two measurement windows<br />

(SPLIT SCREEN) are displayed, traces 1 and 3 are assigned to the upper (SCREEN A) and traces 2<br />

and 4 are assigned to the lower (SCREEN B) measurement window.<br />

The traces can be individually activated for a measurement or frozen after completion of a<br />

measurement. Traces that are not activated are not displayed.<br />

A display mode can be selected for each trace. The traces can be overwritten (CLEAR/WRITE mode)<br />

after each sweep, averaged (AVERAGE mode) over several sweeps, or the maximum/ minimum value<br />

from several sweeps can be displayed (MIN HOLD/MAX HOLD).<br />

Individual detectors are selectable for each of the traces. The auto-peak detector displays the maximum<br />

and minimum values on a vertical line. The max-peak detector and min-peak detector display the<br />

maximum and /minimum levels represented by a pixel. The sampling detector displays the<br />

instantaneous value of the level at a pixel. The rms detector displays the power (rms) of the spectrum at<br />

a pixel, the average detector the average value.<br />

Measurement Function Selection - TRACE 1 to 4 key<br />

The trace functions are categorized as follows:<br />

• type of trace display (CLEAR/WRITE, VIEW and BLANK)<br />

• evaluation of the trace as a whole (AVERAGE, MAX HOLD and MIN HOLD)<br />

• evaluation of the individual pixels of a trace (AUTOPEAK, MAX PEAK, MIN PEAK, SAMPLE, RMS<br />

and AVERAGE)<br />

TRACE 1 menu<br />

TRACE<br />

1 2<br />

TRACE 1<br />

CLEAR/<br />

WRITE<br />

VIEW<br />

TRACE 1<br />

ANALOG TR<br />

ON OFF<br />

3<br />

3<br />

4<br />

BLANK<br />

AVERAGE<br />

TRACE<br />

MATH<br />

MAX HOLD<br />

MIN HOLD<br />

HOLD CONT<br />

ON OFF<br />

ASCII<br />

EXPORT<br />

ASCII<br />

CONFIG<br />

SWEEP<br />

COUNT<br />

DETECTOR<br />

COPY<br />

1088.7531.12 4.226 E-15