Operating Manual EMI TEST RECEIVER ESIB7 - Rohde & Schwarz

Operating Manual EMI TEST RECEIVER ESIB7 - Rohde & Schwarz

Operating Manual EMI TEST RECEIVER ESIB7 - Rohde & Schwarz

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Delta Markers - Analyzer<br />

ESIB<br />

Delta Markers – DELTA Key<br />

The delta marker.s are used to measure a level or frequency referred to a reference marker. They are<br />

always referenced to the marker whose position was last changed. A delta marker is displayed<br />

as an empty symbol. The reference marker is displayed as a filled symbol.<br />

MARKER DELTA menu:<br />

MARKER<br />

NORMAL<br />

SEARCH<br />

DELTA<br />

MARKER<br />

DELTA 1<br />

DELTA 2<br />

The DELTA key switches a delta marker on and calls the<br />

menu for its control. If no marker is enabled, MARKER 1 is<br />

automatically activated when the delta marker is switched on.<br />

The delta marker activated to entry mode is shown on the<br />

display screen as a filled symbol.<br />

DELTA<br />

MKR<br />

DELTA 3<br />

DELTA 4<br />

PHASE<br />

NOISE<br />

REFERENCE<br />

POINT<br />

REFERENCE<br />

FIXED<br />

DELTA MKR<br />

ABS REL<br />

ALL DELTA<br />

OFF<br />

DELTA 1<br />

DE A 2<br />

DELTA 3<br />

DELTA 4<br />

The DELTA 1 to 4 softkeys are used to enable delta markers 1...4. The<br />

control of the delta markers corresponds to that of the markers. After a delta<br />

marker has been enabled, all entries are now applicable to this marker. The<br />

main marker must be activated anew if its position is to be changed.<br />

The delta marker field on the display screen contains the delta marker<br />

number, the difference frequency from the delta marker to reference marker<br />

and the level difference between the active delta markers and reference<br />

markers.<br />

The indicated differences are, in general, referred to the reference marker. If<br />

the PHASE NOISE or REFERENCE FIXED functions are enabled, the<br />

reference values under REFERENCE POINT are applicable.<br />

IEC/IEEE-bus commands<br />

:CALCulate:DELTamarker ON|OFF<br />

:CALCulate:DELTamarker:X 10.7MHZ<br />

:CALCulate:DELTamarker:X:REL?<br />

:CALCulate:DELTamarker:Y<br />

1088.7531.12 4.198 E-15