ESIB<br />

Configuration/Setup<br />

Fig. 4-3<br />

Logarithmic frequency axis and logarithmic interpolation<br />

Fig. 4-4<br />

Logarithmic frequency axis and linear interpolation<br />

Comment - Entry of a comment<br />

The comment can be freely selected. It can have a maximum number of 50<br />

characters.<br />

IEC/IEEE-bus command :[SENS:]CORR:TRAN:COMM <br />

TRD FACTOR<br />

VALUES<br />

INSERT<br />

LINE<br />

DELETE<br />

LINE<br />

The TRD FACTOR VALUES softkey activates the entry for the reference<br />

values of the transducer factor.<br />

The selection bar marks the first reference value. The desired reference<br />

values have to be entered in ascending frequency sequence.<br />

After entering the frequency the selection bar automatically jumps to the<br />

corresponding level value. After entering the first reference value the table<br />

can be edited. The two INSERT LINE and DELETE LINE softkeys are<br />

displayed. Individual values are changed at a later time by marking the field<br />

and by entering the new value.<br />

IEC/IEEE-bus command :[SENS:]CORR:TRAN:DATA<br />

,<br />

The INSERT LINE softkey inserts a free line above the marked reference<br />

value. When entering a new reference value into this line watch out for the<br />

ascending frequency sequence.<br />

The DELETE LINE softkey deletes the marked reference value (the whole<br />

line). The following reference values move up.<br />

IEC/IEEE-bus command --<br />

SAVE TRD<br />

FACTOR<br />

The SAVE TRD FACTOR softkey saves the changed table in a file on the<br />

internal hard disk.<br />

If a transducer factor with the same name already exists, a corresponding<br />

query is performed beforehand.<br />

If the factor to be newly saved is currently switched on, the new values will<br />

immediately be valid. If a transducer set is switched on comprising the factor,<br />

the values will only be used when the set is switched on next time.<br />

IEC/IEEE-bus command - (executed automatically)<br />