Status Reporting System<br />

ESIB<br />

STATus QUEStionable:LIMit Register<br />

This register comprises information about the observance of limit lines. It can be queried with<br />

commands STATus:QUEStionable:LIMit:CONDition? and STATus:QUEStionable:LIMit<br />

[:EVENt]?.<br />

Table 5-7<br />

Meaning of bits in STATus:QUEStionable:LIMit register<br />

Bit No.<br />

Meaning<br />

0 LIMit 1 FAIL<br />

This bit is set if limit line 1 is violated.<br />

1 LIMit 2 FAIL<br />

This bit is set if limit line 2 is violated.<br />

2 LIMit 3 FAIL<br />

This bit is set if limit line 3 is violated.<br />

3 LIMit 4 FAIL<br />

This bit is set if limit line 4 is violated.<br />

4 LIMit 5 FAIL<br />

This bit is set if limit line 5 is violated.<br />

5 LIMit 6 FAIL<br />

This bit is set if limit line 6 is violated.<br />

6 LIMit 7 FAIL<br />

This bit is set if limit line 7 is violated.<br />

7 LIMit 8 FAIL<br />

This bit is set if limit line 8 is violated.<br />

8 not used<br />

9 not used<br />

10 not used<br />

11 not used<br />

12 not used<br />

13 not used<br />

14 not used<br />

15 This bit is always 0.<br />