INPut Subsystem<br />

ESIB<br />

INPut Subsystem<br />

The INPut subsystem checks the input features of the instrument. In receiver mode, the suffix is not<br />

significant. In analyzer mode, a distinction is made between INPut1 (screen A) and INPut2 (screen B) in<br />

the split-screen representation.<br />

INPut<br />

:ATTenuation<br />

:AUTO<br />

:MODE<br />

:PROTection<br />

:UPORt<br />

[:VALue]?<br />

:STATe<br />

:LISN<br />

[:TYPE]<br />

:PHASe<br />

:PEARth<br />

:IMPedance<br />

:CORRection<br />

:MIXer<br />

:COUPling<br />

:GAIN<br />

:STATe<br />

:AUTO<br />

:TYPE<br />

COMMAND PARAMETERS UNIT COMMENT<br />

<br />

<br />

NORMal | LNOise|LDIStortion<br />

<br />

--<br />

<br />

TWOPhase | FOURphase | OFF<br />

L1 | L2 | L3 | N<br />

GROunded | FLOating<br />

50 | 75<br />

RAM | RAZ<br />

<br />

AC | DC<br />

<br />

<br />

INPUT1 |INPUT2<br />

DB<br />

--<br />

--<br />

--<br />

--<br />

--<br />

OHM<br />

DBM<br />

query only<br />

:INPut:ATTenuation 0 to 70 dB<br />

This command programs the input attenuator.<br />

Example: ":INP:ATT 40dB"<br />

Features: *RST value: - (AUTO is set to ON)<br />

SCPI: conforming<br />

Modes:<br />

R, A, VA<br />

The attenuation of the input calibration line can be programmed in steps of 10 dB (INPUT1) and 5 dB<br />

(INPUT2). If the attenuation is programmed directly, the autorange function (receiver) and coupling to<br />

the reference level (analyzer) are switched off.<br />

:INPut:ATTenuation:AUTO ON | OFF<br />

This command activates the auto range function (receiver) or automatically couples the input<br />

attenuation to the reference level. (analyzer).<br />

Example: ":INP:ATT:AUTO ON"<br />

Features: *RST value: ON<br />

SCPI: conforming<br />

Modes:<br />

R, A, VA<br />

1088.7531.12 6.82 E-15