ESIB<br />

Display Configuration<br />

<strong>EMI</strong> <strong>RECEIVER</strong> mode:<br />

In the <strong>RECEIVER</strong> mode, a selection can be made in the upper half of the screen (SCREEN A) between<br />

bargraph display of the receiver mode and the spectrum analyzer mode.<br />

With spectrum analyzer selected, the scan display in the lower half of the screen remains unchanged<br />

and the spectrum analyzer with all its measurement functions is available in the upper screen half.<br />

It is therefore possible to perform first a premeasurement with a scan and then to further investigate<br />

suspect signals with the aid of the spectrum analyzer, eg in the zero span to determine time<br />

characteristics. The center frequency of the spectrum analyzer can be coupled to the marker frequency<br />

of the scan display so that the frequencies to be analyzed can be easily displayed in the spectrum<br />

analyzer.<br />

ACTIVE<br />

SCREEN A<br />

ACTIVE<br />

SCREEN B<br />

If SPLIT SCREEN display is activated, the ACTIVE SCREEN A and ACTIVE<br />

SCREEN B softkeys activate either screen A or screen B.<br />

The entry of new settings is only possible for the active window.<br />

When switching back to FULL SCREEN mode, the active measurement<br />

window is displayed.<br />

These softkeys are only displayed if operation with two independent channels<br />

and different softkey menus - receiver with scan display and spectrum<br />

analyzer - is selected (SCREEN A SWEEP). Only in this case will it be<br />

necessary to assign entries to the receiver or to the spectrum analyzer.<br />

IEC/IEEE bus command - (the screen is selected via the numeric suffix)<br />

SCREEN A<br />

BARGRAPH<br />

The SCREEN A BARGRAPH softkey switches on the bargraph display in the<br />

upper half of the screen (SCREEN A).<br />

IEC/IEEE bus command :INSTrument[1][:SELect] RECeiver<br />

SCREEN A<br />

SWEEP<br />

The SCREEN A SWEEP softkey switches on the analyzer mode in the upper<br />

half of the screen (SCREEN A).<br />

The softkeys of all menus are assigned the analyzer functions. An exception<br />

is the DISPLAY menu where the SCREEN A BARGRAPH softkey is<br />

displayed to allow a return to the bargraph display of the receiver mode.<br />

IEC/IEEE bus command :INSTrument[1][:SELect] SANalyzer<br />

RUN SCAN<br />

The RUN SCAN softkey starts the frequency scan with the selected settings.<br />

(see Section "Frequency Scan").<br />

ANALYZER mode:<br />

ACTIVE<br />

SCREEN A<br />

ACTIVE<br />

SCREEN B<br />

If SPLIT SCREEN display is activated, the ACTIVE SCREEN A and ACTIVE<br />

SCREEN B softkeys activate either screen A or screen B.<br />

The entry of new settings is only possible for the active window.<br />

When switching back to FULL SCREEN mode, the active measurement<br />

window is displayed.<br />

If, in addition, the two screens are both subdivided into two diagrams, the<br />

ACTIVE SCREEN A/B softkeys activate the upper diagram, ACTIVE<br />

SCREEN C/D the lower diagram in each screen.<br />

IEC/IEEE- bus command - (the screen is selected via the numeric suffix)<br />