Frequency and Span - Analyzer<br />

ESIB<br />

Display Zoom<br />

FREQUENCY SPAN- ZOOM submenu:<br />

ZOOM<br />

ZOOM<br />

MOVE ZOOM<br />

WINDOW<br />

MOVE ZOOM<br />

START<br />

MOVE ZOOM<br />

STOP<br />

ZOOM<br />

OFF<br />

.<br />

.<br />

.<br />

The ZOOM softkey activates the zoom mode and opens a<br />

sub-menu to define the zoom span.<br />

Two frequency lines, which show and define the frequency<br />

range to be zoomed, appear in the active measurement<br />

window when the zoom mode is switched on. The default<br />

setting is a zoom span of 10% to the left and 10% to the right<br />

of the center frequency. The zoomed display is shown in the<br />

second measurement window.<br />

The settings for the second measurement window are taken<br />

from the original window. The second measurement window<br />

thus becomes the active measurement window and its<br />

settings can now be changed.<br />

If only one window is active when the zoom function is<br />

selected, SPLIT SCREEN mode is automatically switched on.<br />

The zoom span can be edited by using the softkeys of the<br />

sub-menu to change the position of the frequency lines.<br />

The softkey ZOOM OFF switches off the zoom.<br />

MOVE ZOOM<br />

WINDOW<br />

The MOVE ZOOM WINDOW softkey shifts the whole zoom window. The<br />

window can shifted until the upper frequency line reaches the stop frequency<br />

or the lower frequency line reaches the start frequency of the original window.<br />

IEC/IEEE-bus commands<br />

:DISPlay[:WINDow]:TRACe:X[:SCALe]:ZOOM ON<br />

:DISPlay[:WINDow]:TRACe:X:ZOOM:CENTer 1GHz<br />

MOVE ZOOM<br />

START<br />

The MOVE ZOOM START softkey shifts the lower frequency line. The start<br />

frequency of the zoomed display can then be modified. The frequency line<br />

can be shifted to the start frequency of the original window or to the upper<br />

frequency line (= zero span).<br />

IEC/IEEE-bus commands<br />

:DISPlay[:WINDow]:TRACe:X[:SCALe]:ZOOM ON<br />

:DISPlay[:WINDow]:TRACe:X:ZOOM:STARt 100MHz<br />

MOVE ZOOM<br />

STOP<br />

The MOVE ZOOM STOP softkey shifts the upper frequency line. Thus, the<br />

stop frequency of the zoomed display can be modified. The frequency line<br />

can be shifted to the stop frequency of the original window or to the lower<br />

frequency line (= zero span).<br />

IEC/IEEE-bus commands<br />

:DISPlay[:WINDow]:TRACe:X[:SCALe]:ZOOM ON<br />

:DISPlay[:WINDow]:TRACe:X:ZOOM:STOP 200MHz<br />

ZOOM<br />

OFF<br />

The ZOOM OFF softkey switches the zoom function off and then returns<br />

control to the main menu.<br />

The frequency lines indicating the zoom range are deleted, SPLIT SCREEN<br />

mode remains active, the settings of both measurement windows are<br />

retained and the coupling of the two measurement windows is cancelled.<br />

IEC/IEEE-bus command<br />

:DISPlay[:WINDow]:TRACe:X[:SCALe]:ZOOM OFF<br />

1088.7531.12 4.164 E-15