ESIB<br />

CALCulate Subsystem<br />

:CALCulate:MARKer:FUNCtion:POWer:RESult? ACPower | CPOWer | OBANdwidth |<br />

OBWidth | CN | CN0<br />

This command queries the results of the power measurement (see also CALCulate:MARKer:<br />

FUNCtion:POWer:SELect.)<br />

Example: ":CALC:MARK:FUNC:POW:RES? OBW"<br />

Features: *RST value: -<br />

SCPI: device-specific<br />

Modes:<br />

A, VA<br />

ACPower adjacent channel power measurement; Results are output separated by commas<br />

in the following order: Power of main channel<br />

Power of lower adjacent channel 1<br />

Power of upper adjacent channel 1<br />

Power of lower adjacent channel 2<br />

Power of upper adjacent channel 2<br />

...<br />

The number of results depends on the number of adjacent channels selected.<br />

With logarithmic scaling (RANGE LOG), the power is output in dBm, with linear<br />

scaling (RANGE LIN dB or LIN %) in W. If SENSe:POWer:ACHannel:MODE REL<br />

is selected, adjacent channel power is output in dB.<br />

CPOWer channel power measurement<br />

With logarithmic scaling (RANGE LOG), the channel power is output in dBm, with<br />

linear scaling (RANGE LIN dB or LIN %) in W.<br />

OBANdwidth | OBWidth occupied bandwidth power measurement<br />

The return value is the occupied bandwidth in Hz<br />

CN<br />

signal / noise power measurement<br />

The return value is always in dB..<br />

CN0<br />

signal-/ noise power measurement based on 1Hz bandwidth<br />

The return value is always in dB/Hz<br />

This command is only a query which is why it is not assigned an *RST value.<br />

:CALCulate:MARKer:FUNCtion:POWer[:STATe] OFF<br />

This command switches the power measurement off.<br />

Example: ":CALC:MARK:FUNC:POW OFF"<br />

Features: *RST value: -<br />

SCPI: device-specific<br />

Modes:<br />

A-F, VA-D<br />

This command is an event which is why it is not assigned an *RST value.<br />