ESIB<br />

Receiver - Data Reduction and Peak List<br />

INTER<br />

ACTIVE<br />

The INTERACTIVE softkey selects the following sequence for the final<br />

measurement:<br />

• A frequency from the frequency list is set on the receiver together with<br />

the associated settings from the corresponding partial scan.<br />

• The marker is set on this frequency in the scan diagram.<br />

• The final measurement sequence switches to the Interrupted status.<br />

• The signal can be exactly analyzed by modifying the receiver settings.<br />

• CONTINUE AT HOLD starts the actual final measurement, the receiver<br />

settings being restored except the frequency.<br />

• The current frequency replaces the original one in the frequency list<br />

(drifting interference sources)<br />

• Next frequency of frequency list.....<br />

Note:<br />

With the AUTOMATIC FINAL softkey in the CONTINUE FINAL<br />

MEAS submenu a switchover can be made to the automatic<br />

mode before the measurement is started anew.<br />

IEC/IEEE-bus command --<br />

RUN<br />

FINAL MEAS<br />

HOLD<br />

FINAL MEAS<br />

HOLD<br />

FINAL MEAS<br />

STOP<br />

FINAL MEAS<br />

The RUN FINAL MEAS softkey starts the final measurement<br />

sequence as described above. The HOLD FINAL MEAS<br />

submenu is called.<br />

The detectors used for the final measurement replace those<br />

used in the list or for the prescan.<br />

The out-of-limit condition is shown by a plus sign preceding the<br />

values in the DELTA LIMIT column (see table below).<br />

IEC/IEEE-bus command --<br />

Note:<br />

The final measurement function is only available in the<br />

manual mode. For operation under program control it<br />

is preferable to read the prescan results and the datareduced<br />

peak list, if any, from the ESIB with the<br />

controller and carry out the individual measurements<br />

with the controller. This considerably makes the<br />

control of the interactive mode easier.<br />

1088.7531.12 4.105 E-15