Search Functions - Analyzer<br />

ESIB<br />

ACTIVE<br />

MKR DELTA<br />

The ACTIVE MKR / DELTA softkey toggles between the active marker and<br />

the active delta marker.<br />

If DELTA is illuminated, the following search functions are performed with the<br />

active delta marker.<br />

Note:<br />

Switching between marker and delta marker entry modes may<br />

also be performed using the NORMAL and DELTA keys.<br />

IEC/IEEE-bus command --<br />

SELECT<br />

MARKER<br />

The SELECT MARKER softkey activates the selection of the marker/delta<br />

markers. The selection box lists the currently enabled markers/delta markers.<br />

MARKER SELECT<br />

MARKER 1<br />

MARKER 3<br />

MARKER 4<br />

DELTA SELECT<br />

DELTA 1<br />

DELTA 2<br />

DELTA 3<br />

IEC/IEEE-bus command --<br />

PEAK<br />

The PEAK softkey sets the active marker/delta marker to the maximum<br />

displayed value on the corresponding trace.<br />

IEC/IEEE-bus commands<br />

:CALCulate:MARKer:MAXimum<br />

:CALCulate:DELTamarker:MAXimum<br />

NEXT PEAK<br />

The NEXT PEAK softkey sets the active marker/delta marker to the trace<br />

value next in magnitude after the peak.<br />

IEC/IEEE-bus commands<br />

:CALCulate:MARKer:MAX:NEXT<br />

:CALCulate:DELTamarker:MAX:NEXT<br />

NEXT PEAK<br />

The NEXT PEAK RIGHT softkey sets the active marker to the next peak to<br />

the right of the current marker position.<br />

IEC/IEEE-bus commands<br />

:CALCulate:MARKer:MAX:RIGHt<br />

:CALCulate:DELTamarker:MAX:RIGHt<br />

NEXT PEAK<br />

RIGHT<br />

The NEXT PEAK LEFT softkey sets the active marker to the next peak to the<br />

left of the current marker position.<br />

IEC/IEEE-bus commands<br />

:CALCulate:MARKer:MAX:LEFT<br />

:CALCulate:DELTamarker:MAX:LEFT<br />

MIN<br />

The MIN softkey sets the active marker to minimum displayed value on the<br />

corresponding trace.<br />

IEC/IEEE-bus commands<br />

:CALCulate:MARKer:MIN<br />