Display and Limit Lines - Analyzer<br />

ESIB<br />

TIME<br />

LINE 1<br />

TIME<br />

LINE 2<br />

The TIME LINE 1/2 softkeys switch the time lines 1/2 on/off and activate the<br />

entry of line locations.<br />

The time lines mark the selected times or define the search range (see<br />

section "Marker Functions").<br />

IEC/IEEE-bus commands<br />

:CALCulate:TLINe:STATe ON | OFF;<br />

:CALCulate:TLINe 10ms<br />

BASELINE<br />

CLIPPING<br />

The BASELINE CLIPPING softkey switches on or off the BASELINE<br />

CLIPPING function and allows a limit value to be entered.<br />

The BASELINE CLIPPING function is for blanking measured values (for<br />

example noise) which are below a preset threshold.<br />

If the BASELINE CLIPPING function is active and a measured value is below<br />

the preset threshold, the value is set to a lower boundary (-400 dBm).<br />

Measured values above the clipping level are not changed.<br />

Note:<br />

It is advisable not to combine the BASELINE CLIPPING function<br />

with the AUTOPEAK detector.<br />

If the set clipping value is within the displayed noise band<br />

(AUTOPEAK detector), activation of the CLIPPING function and<br />

the resulting clipping of the MIN PEAK values will lead to a drastic<br />

enlargement of the displayed noise band.<br />

IEC/IEEE-bus commands<br />

:CALCulate:CTHReshold:STATe ON | OFF<br />

:CALCulate:CTHReshold -82dBm<br />

1088.7531.12 4.216 E-15