ESIB<br />

Recalling Data Sets<br />

Selecting the Data Set for Recalling<br />

MEMORY RECALL menu:<br />

EDIT<br />

NAME<br />

The EDIT NAME softkey activates the entry of a data set name.<br />

The data input is terminated by pressing one of the units keys which<br />

simultaneously initiates the data set recall operation.<br />

IEC/IEEE-bus command :MMEMory:LOAD:STATe 1,’A:test’<br />

EDIT<br />

PATH<br />

The EDIT PATH softkey activates the entry of a directory name in which the<br />

data set is located. Default path is c:\user\config.<br />

IEC/IEEE-bus command --<br />

AUTO<br />

RECALL<br />

The AUTO RECALL softkey activates the selection of a data set which will be<br />

automatically recalled when the instrument is powered up. The DATA SET<br />

LIST/CONTENT table is opened to make the selection (analogous to DATA<br />

SET LIST).<br />

IEC/IEEE-bus command<br />

:MMEMory:LOAD:AUTO 1,’C:\user\data\auto’<br />

DATA SET LIST<br />

DATASET1<br />

DATASET2<br />

DATASET3<br />

AUTO RECALL SET CONTENT<br />

CONTENTS<br />

GENERAL SETUP<br />

HW-SETTINGS<br />

TRACE 1<br />

TRACE 2<br />

TRACE 3<br />

TRACE 4<br />

LINES<br />

CVL TABLES<br />

COLOR SETUP<br />

HARDCOPY<br />

MACROS<br />

TRANSDUCER<br />

COMMENT<br />

GSM_MASK<br />

The DATA SET LIST column displays all the data sets in the selected<br />

directory.<br />

The CONTENTS and COMMENT lines in the AUTO RECALL CONTENTS<br />

column indicate the saved data subsets and the comments for the currently<br />

selected data set.<br />

In addition to the data sets saved by the user, the data set FACTORY, which<br />

contains the settings of the instrument before it was last switched off<br />

(Standby), is always included.<br />

If a data set other than FACTORY is chosen the data subsets in the selected<br />

data set that are available are recalled when the ESIB is powered up. The<br />

data subsets which are not in this data set are taken from the FACTORY data<br />

set.<br />

Note:<br />

The selected data set is also loaded on PRESET if AUTO RECALL<br />

is active. The preset settings can then be configured as required.<br />