04.02.2013 Views

Regional Basic Professional Training Course in Korea

Regional Basic Professional Training Course in Korea

Regional Basic Professional Training Course in Korea

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Regional</strong> <strong>Basic</strong> <strong>Professional</strong> <strong>Tra<strong>in</strong><strong>in</strong>g</strong> <strong>Course</strong> (BPTC) on Nuclear Safety<br />

o Report<strong>in</strong>g Requirement<br />

(MEST Notice 2008-29)<br />

o Other Safety Significant Event Report<br />

Report<strong>in</strong>g of unusual event<br />

No Screen<strong>in</strong>g Criteria<br />

(under development)<br />

Spot <strong>in</strong>vestigation<br />

Root cause analysis<br />

Safety<br />

Economical efficiency<br />

o Not likely to impact on safety<br />

o Not likely to have a significant<br />

effect on safety<br />

o Likely to have a significant<br />

effect on safety<br />

Screen<strong>in</strong>g &<br />

Storage<br />

Investigation & Analysis<br />

Corrective actions<br />

Trend<strong>in</strong>g & Review<br />

Dissem<strong>in</strong>ation/Utilization<br />

Monitor Effectiveness<br />

❙ 1144 ❙<br />

o About 3000 cases of IAEA (AIRS), USNRC GL<br />

NUSIRC, Canada, OECD/ NEA<br />

o About 550 cases of Domestic NPPs<br />

Data Gather<strong>in</strong>g<br />

OPIS Database<br />

Process analysis code,<br />

Nuclear Plant Analyzer (e-FAST) ,<br />

3D Virtual Nuclear Power Plant<br />

Information System<br />

MOST, KINS, KHNP<br />

Implementation of CNS<br />

Implementation of cooperat<strong>in</strong>g<br />

duty between countries<br />

Improve Design, Operation, Ma<strong>in</strong>tenance, Inspection & Test us<strong>in</strong>g Operational Experience<br />

to Get Safety Goals (Accident Prevention)<br />

[Fig. 1.1] Schematic diagram of Operational Experience Feedback<br />

Accurate analysis of the operat<strong>in</strong>g characteristics of nuclear power plants provides<br />

valuable <strong>in</strong>formation for both normal and abnormal operation. The <strong>in</strong>formation can be<br />

used for the enhancement of plant performance and safety. Usually, such analysis is<br />

performed us<strong>in</strong>g computer codes used for plant design or full scale simulators. However,<br />

their usages are limited because special expertise is required to use the computer codes<br />

and the simulators are not portable. Therefore, it deemed necessary to develop an Nuclear<br />

Plant Analyzer(NPA) which m<strong>in</strong>imizes those limitations and can be used for the analysis<br />

and simulation of nuclear power plants.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!