<strong>Regional</strong> <strong>Basic</strong> <strong>Professional</strong> <strong>Tra<strong>in</strong><strong>in</strong>g</strong> <strong>Course</strong> (BPTC) on Nuclear Safety<br />

to ma<strong>in</strong>ta<strong>in</strong> the safety functions and performance of safety‐related structures, systems and<br />

components as assumed and <strong>in</strong>tended <strong>in</strong> design.<br />

For this purpose, the follow<strong>in</strong>g actions shall be taken <strong>in</strong> accordance with government<br />

notices;<br />

The degree of degradation <strong>in</strong> materials and performance of safety‐related<br />

structures, systems, and components due to age<strong>in</strong>g shall be monitored and<br />

evaluated, and necessary measures shall be taken;<br />

For the pumps and valves necessary for safety shutdown, core cool<strong>in</strong>g, and<br />

mitigation of accident consequences, their performance and degree of degradation<br />

due to age<strong>in</strong>g shall be monitored and evaluated, and necessary measures shall be<br />

taken;<br />

For the reactor pressure vessel, the degree of degradation <strong>in</strong> material and<br />

performance due to neutron irradiation shall be monitored and evaluated, and<br />

necessary measures shall be taken;<br />

Verification and calibration of <strong>in</strong>strumentation and radiation detector directly<br />

related with preservation of reactor facilities shall be conducted at the specified<br />

period.<br />

Test<strong>in</strong>g, monitor<strong>in</strong>g, and ma<strong>in</strong>tenance activities shall be performed by qualified personnel<br />

<strong>in</strong> accordance with the government notices.<br />

12.5.2. Regulatory Notice for <strong>in</strong>‐service test of pumps and valves<br />

The licensee shall establish and perform pre‐service test program dur<strong>in</strong>g <strong>in</strong>itial operation<br />

period to acquire base data for <strong>in</strong>‐service test such as pump performance curve, reference<br />

❙ 786 ❙