<strong>Regional</strong> <strong>Basic</strong> <strong>Professional</strong> <strong>Tra<strong>in</strong><strong>in</strong>g</strong> <strong>Course</strong> (BPTC) on Nuclear Safety<br />

performed <strong>in</strong> the presence of the expert on the basis of a test program certified by the<br />

tester <strong>in</strong> advance.<br />

The <strong>in</strong>tervals and the extent of these surveillance programs are laid down between the<br />

operator and the expert, and <strong>in</strong> accordance with the recommendations of the<br />

manufacturer, and are primarily based on the standpo<strong>in</strong>t that the <strong>in</strong>terval must be chosen<br />

so the reliability considerations of the system and plant as a whole are not adversely<br />

affected. In a similar way, the time available for each activity on a certa<strong>in</strong> component or<br />

system is once aga<strong>in</strong> the product of availability considerations together with fulfillment<br />

of safety criteria for the nuclear power plant <strong>in</strong> the case of an <strong>in</strong>cident and its capability of<br />

cop<strong>in</strong>g with this <strong>in</strong>cident. In general, the experience and the guidel<strong>in</strong>es from conventional<br />

rules and regulations have a significant <strong>in</strong>fluence on these two parameters.<br />

The surveillance programs are performed as approved by regulatory body and the<br />

surveillance results are reviewed as required by regulatory body, too. The programs are<br />

made upon the requirement described <strong>in</strong> plant technical specification and f<strong>in</strong>al safety<br />

analysis report for the given plant. Any changes from the orig<strong>in</strong>al programme are<br />

subjected to the approval of regulatory body.<br />

12.4.2. Monitor<strong>in</strong>g<br />

Monitor<strong>in</strong>g systems can be divided <strong>in</strong>to two categories. There are permanently <strong>in</strong>stalled<br />

monitors and mobile monitors. Mobile monitors are usually used <strong>in</strong> radiation safety.<br />

Examples are survey meters, dose rate monitor<strong>in</strong>g, contam<strong>in</strong>ation monitors or laboratory<br />

<strong>in</strong>struments. The permanently <strong>in</strong>stalled monitors are, <strong>in</strong> case of radiation safety, such as<br />

permanent dose rate <strong>in</strong>stallations, measurement of exhaust air activity for noble gasses,<br />

aerosols and iod<strong>in</strong>e, or measurement of activity <strong>in</strong> the secondary cool<strong>in</strong>g circuit. All those<br />