❙ 787 ❙<br />

12. Surveillance Programmes<br />

values of pumps and valves needed to compare, analyze and evaluate performance<br />

change dur<strong>in</strong>g plant operation.<br />

For motor‐ and pneumatically‐operated valves, design basis performance evaluation<br />

program shall be established and implemented additionally to evaluate design basis<br />

operation marg<strong>in</strong>.<br />

The licensee shall establish and implement <strong>in</strong>‐service test program spann<strong>in</strong>g every 10<br />

years after commencement of commercial operation. Provided, that for motor‐ and<br />

pneumatically‐operated valve, additional evaluation program shall be established and<br />

implemented.<br />

Initial reference values shall be determ<strong>in</strong>ed from the results of pre‐service test or <strong>in</strong>itial <strong>in</strong><br />

‐service test. When a reference value or set of values may have been affected by repair,<br />

replacement, or ma<strong>in</strong>tenance activities, a new reference values or set of values shall be<br />

evaluated and determ<strong>in</strong>ed whether the values demonstrate adequate operability.<br />

Records or data of pre‐service test and <strong>in</strong>‐service test shall be ma<strong>in</strong>ta<strong>in</strong>ed as set forth <strong>in</strong><br />

the quality assurance program;<br />

Pre‐service and <strong>in</strong>‐service test program and its change<br />

Design basis performance evaluation program, periodic performance evaluation<br />

program or motor‐ and pneumatically‐operated vales and their changes<br />

Pre‐service and <strong>in</strong>‐service test results<br />

Reasons of resett<strong>in</strong>g of reference values and evaluation results of operation status<br />

Cause of excessiveness of allowable range and evaluation results<br />

History of request for exemption and records of request basis