04.02.2013 Views

Regional Basic Professional Training Course in Korea

Regional Basic Professional Training Course in Korea

Regional Basic Professional Training Course in Korea

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Regional</strong> <strong>Basic</strong> <strong>Professional</strong> <strong>Tra<strong>in</strong><strong>in</strong>g</strong> <strong>Course</strong> (BPTC) on Nuclear Safety<br />

phenomena of the process <strong>in</strong>strumentation. To achieve operational flexibility, it is<br />

recommended that actual trip po<strong>in</strong>ts, where possible, be set more conservatively than<br />

specification values.<br />

10.6.2.1 Criteria : Reactors with or without Eng<strong>in</strong>eered Cool<strong>in</strong>g System<br />

An LSSS shall be specified for automatic protection devices related to those variables<br />

hav<strong>in</strong>g safety limits.<br />

10.7. LIMITING CONDITIONS FOR<br />

OPERATIONS<br />

10.7.1. Reactor Core Parameters<br />

Limits shall be established for the follow<strong>in</strong>g: (1) excess reactivity; (2) shutdown marg<strong>in</strong>;<br />

(3) pulse limits (e.g., reactivity, peak power, energy, fuel temperature); (4) core<br />

configurations; (5) fuel burnup, as appropriate; (6) fuel <strong>in</strong>spection, if appropriate.<br />

10.7.2. Reactor Control and Safety Systems<br />

The follow<strong>in</strong>g shall be specified: (1) m<strong>in</strong>imum number of operable control rods (operable<br />

to be specified <strong>in</strong> terms of maximum scram times); (2) maximum reactivity <strong>in</strong>sertion rate<br />

❙ 678 ❙