8-A. Determ<strong>in</strong>istic Accident Analysis (Non‐LOCA)<br />

isolation of ventilation systems may be assumed to take place accord<strong>in</strong>g to the design of<br />

the plant system so that any changes <strong>in</strong> the parameters, used as protection limits dur<strong>in</strong>g<br />

accidents, are assessed conservatively.<br />

Before isolation, ventilation has to be assumed to function <strong>in</strong> the normal way. After<br />

isolation, radioactive substances have to be assumed to mix with the gaseous volume of<br />

the whole conta<strong>in</strong>ment. The conta<strong>in</strong>ment leak rate has to be selected tak<strong>in</strong>g <strong>in</strong>to account<br />

the tightness requirement set up for the conta<strong>in</strong>ment and the conta<strong>in</strong>ment overpressure<br />

calculated dur<strong>in</strong>g the analysis of postulated accidents. Appropriate safety marg<strong>in</strong>s need to<br />

be employed for the selection.<br />

The halogens which have leaked from the conta<strong>in</strong>ment should be assumed to be partly <strong>in</strong><br />

<strong>in</strong>organic compounds and partly <strong>in</strong> organic compounds. The distribution <strong>in</strong>to the various<br />

k<strong>in</strong>ds of compound needs to be justified. The releases caused by the leaks and the<br />

potential malfunctions of the ECCS and the leaks of the conta<strong>in</strong>ment cool<strong>in</strong>g systems<br />

outside the conta<strong>in</strong>ment boundary have to be taken <strong>in</strong>to account conservatively.<br />

The ventilation of the space surround<strong>in</strong>g the conta<strong>in</strong>ment has to be assumed to function <strong>in</strong><br />

the way designed for accident conditions, and the releases aris<strong>in</strong>g from a conta<strong>in</strong>ment<br />

leak need to be calculated accord<strong>in</strong>gly. If the ventilation system is used <strong>in</strong> the normal way<br />

with the filters bypassed, the time spent <strong>in</strong> the possible switch over to the filters has to be<br />

justified.