04.02.2013 Views

Regional Basic Professional Training Course in Korea

Regional Basic Professional Training Course in Korea

Regional Basic Professional Training Course in Korea

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Regional</strong> <strong>Basic</strong> <strong>Professional</strong> <strong>Tra<strong>in</strong><strong>in</strong>g</strong> <strong>Course</strong> (BPTC) on Nuclear Safety<br />

eddy current test<strong>in</strong>g (ECT) for steam generator tubes. The test specimen for UT<br />

performance demonstration shall be selected among those represent<strong>in</strong>g characteristics of<br />

size, materials, configuration, etc. of safety related facilities of domestic PWR and<br />

PHWR. In case of ECT for steam generator tubes, the performance demonstration shall<br />

be supplemented for each nuclear power plant by us<strong>in</strong>g data of characteristics of the<br />

plant.<br />

Personnel qualified <strong>in</strong> accordance with performance demonstration shall be re‐qualified<br />

every 5 years. Provided, that re‐qualification for UT performance demonstration is<br />

required only once.<br />

The licensee may apply the other standards or guidel<strong>in</strong>es equivalent to those def<strong>in</strong>ed <strong>in</strong><br />

the Notice or utilize the new methods or procedures appropriate for the <strong>in</strong>‐service<br />

<strong>in</strong>spection (alternative application), and also, he may request relief or exemption from<br />

any part of the standards (relief request), <strong>in</strong> one of the follow<strong>in</strong>g cases not reduc<strong>in</strong>g<br />

reliability of nuclear reactor facilities and <strong>in</strong>tegrity of related facilities:<br />

In case that the <strong>in</strong>spection can neither be conducted nor meet the standards due to<br />

characteristics of design, configuration and materials of the components or systems<br />

subject to exam<strong>in</strong>ation or test;<br />

In case that the workers are anticipated to be over‐exposed to high radiation <strong>in</strong> spite<br />

of considerable protective action taken;<br />

In case that alternative application or relief request does not reduce appropriate<br />

quality and safety; or<br />

In case that quality and safety improvement to be achieved by the <strong>in</strong>spection<br />

accord<strong>in</strong>g to the standards of Article 6 do not compensate for the difficulty and risk<br />

of the work<strong>in</strong>g activity.<br />