commission<strong>in</strong>g process.<br />

❙ 869 ❙<br />

15. Operational Safety<br />

To confirm the applicability and quality of the operat<strong>in</strong>g procedures, they are verified to<br />

ensure their technical accuracy, and are validated to ensure their usability with the<br />

<strong>in</strong>stalled equipment and controls as far as possible prior to load<strong>in</strong>g fuel <strong>in</strong>to the core. This<br />

process cont<strong>in</strong>ues dur<strong>in</strong>g the commission<strong>in</strong>g phase. This prelim<strong>in</strong>ary verification and<br />

validation process also applies to ma<strong>in</strong>tenance, surveillance and chemistry procedures, as<br />

appropriate.<br />

The operat<strong>in</strong>g organization ensures that the commission<strong>in</strong>g program <strong>in</strong>cludes all the tests<br />

necessary to demonstrate that the plant as <strong>in</strong>stalled meets the requirements of the FSAR,<br />

satisfies the design <strong>in</strong>tent, and consequently can be operable <strong>in</strong> accordance with the<br />

LCOs. The tests are carried out <strong>in</strong> a logical order. Tests that may place the plant <strong>in</strong> a<br />

condition that has not been analyzed shall not be performed. The program ensures that<br />

system and component “base l<strong>in</strong>e” data, important to safety of the plant and for<br />

subsequent safety reviews, is collected and reta<strong>in</strong>ed.<br />

From the start of commission<strong>in</strong>g, adequate work control and modification procedures are<br />

implemented to ensure that the commission<strong>in</strong>g tests are not <strong>in</strong>validated by subsequent<br />

<strong>in</strong>tervention on the plant. These procedures are the same as those <strong>in</strong>tended for the<br />

operat<strong>in</strong>g phase.<br />

From construction to commission<strong>in</strong>g, and f<strong>in</strong>ally to operation, the plant is adequately<br />

monitored and ma<strong>in</strong>ta<strong>in</strong>ed <strong>in</strong> order to protect the equipment, support the test<strong>in</strong>g phase and<br />

cont<strong>in</strong>ue to satisfy the SAR. Records of operations and ma<strong>in</strong>tenance are produced from<br />

the <strong>in</strong>itial energiz<strong>in</strong>g and operation of each plant system, and are reta<strong>in</strong>ed by the<br />

operat<strong>in</strong>g organization <strong>in</strong> proper archive facilities for periods as agreed with the<br />

regulatory body.