<strong>Regional</strong> <strong>Basic</strong> <strong>Professional</strong> <strong>Tra<strong>in</strong><strong>in</strong>g</strong> <strong>Course</strong> (BPTC) on Nuclear Safety<br />

Test<strong>in</strong>g of the operability and tightness of closure devices that are part of the<br />

boundaries;<br />

Monitor<strong>in</strong>g leak detection systems (process and area radiation <strong>in</strong>struments,<br />

temperature detectors, acoustic detection equipment, etc.);<br />

Monitor<strong>in</strong>g to assure that transition (e.g. reference nil‐ductility) temperature<br />

considerations are satisfied;�<br />

Monitor<strong>in</strong>g the chemical quality of the primary or secondary reactor coolants as<br />

appropriate;<br />

Monitor<strong>in</strong>g the samples subject to irradiation of reactor pressure vessel<br />

components. Surveillance measures necessary to verify conta<strong>in</strong>ment <strong>in</strong>tegrity<br />

<strong>in</strong>clude:<br />

Leak rate tests performed on the conta<strong>in</strong>ment;<br />

Tests of penetration seals and closure devices such as air locks and valves that are<br />

part of the boundaries to demonstrate their leak tightness and, where appropriate,<br />

their operability;<br />

Structural <strong>in</strong>tegrity <strong>in</strong>spections (e.g. those performed on l<strong>in</strong>er and pre‐stress<strong>in</strong>g<br />

tendons);<br />

Monitor<strong>in</strong>g conditions with<strong>in</strong> the conta<strong>in</strong>ment such as temperatures, pressures and<br />

atmospheric composition.<br />

The surveillance programme <strong>in</strong>cludes periodic tightness checks, pressure and/or leak tests<br />

of all systems, parts of which are outside the conta<strong>in</strong>ment and which could conta<strong>in</strong> highly<br />

radioactive liquids or gases follow<strong>in</strong>g an accident. Examples of these systems are:<br />

Residual heat removal systems;<br />

Safety <strong>in</strong>jection systems;<br />