<strong>Regional</strong> <strong>Basic</strong> <strong>Professional</strong> <strong>Tra<strong>in</strong><strong>in</strong>g</strong> <strong>Course</strong> (BPTC) on Nuclear Safety<br />

guidel<strong>in</strong>es. The procedures shall <strong>in</strong>clude management commitment and programs<br />

to ma<strong>in</strong>ta<strong>in</strong> exposures and releases as low as reasonably achievable <strong>in</strong><br />

accordance with the guidel<strong>in</strong>es;<br />

(6) adm<strong>in</strong>istrative controls for operations and ma<strong>in</strong>tenance and for the conduct of<br />

irradiations and experiments that could affect reactor safety or core reactivity;<br />

(7) implementation of required plans such as emergency or security plans;<br />

(8) use, receipt, and transfer of by‐product material, if appropriate.<br />

10.10.5. Experiments Review and Approval<br />

Approved experiments shall be carried out <strong>in</strong> accordance with established and approved<br />

procedures. The follow<strong>in</strong>g provisions shall be stated:<br />

(1) All new experiments or class of experiments shall be reviewed by the review<br />

group and approved <strong>in</strong> writ<strong>in</strong>g by Level 2 (Senior Reactor Operators) or<br />

designated alternates prior to <strong>in</strong>itiation;<br />

(2) Substantive changes to previously approved experiments shall be made only after<br />

review by the review group and approved <strong>in</strong> writ<strong>in</strong>g by Level 2 (Senior Reactor<br />

Operators) or designated alternates. M<strong>in</strong>or changes that do not significantly alter<br />

the experiment may be approved by Level 3 (Reactor Operators) or higher.<br />

10.10.6. Required Actions<br />

10.10.6.1. Action to be taken <strong>in</strong> case of safety limits violation<br />

(1) The reactor shall be shut down, and reactor operations shall not be resumed until<br />