<strong>Regional</strong> <strong>Basic</strong> <strong>Professional</strong> <strong>Tra<strong>in</strong><strong>in</strong>g</strong> <strong>Course</strong> (BPTC) on Nuclear Safety<br />

Control of noncompliance and/or deficiencies found <strong>in</strong> the process of design and<br />

fabrication of major components are adequate.<br />

Control and evaluation of contracted items and services are adequately<br />

implemented.<br />

Manufacturer Inspection: Manufacturer <strong>in</strong>spections are also performed as scheduled<br />

<strong>in</strong>spections. This <strong>in</strong>spection should determ<strong>in</strong>e consider<strong>in</strong>g safety importance and<br />

<strong>in</strong>formation from external sources whether there are deficiencies <strong>in</strong> design, fabrication<br />

and test<strong>in</strong>g process, or defects <strong>in</strong> the items, and whether appropriate corrective measures<br />

are taken to those deficiencies and/or defects. If necessary for this purpose, reactive<br />

<strong>in</strong>spections may be performed <strong>in</strong> addition to scheduled <strong>in</strong>spections. The follow<strong>in</strong>gs shall<br />

be determ<strong>in</strong>ed <strong>in</strong> manufacturer <strong>in</strong>spections:<br />

Whether quality assurance standards (Article 68 or Article 85 of Regulations on<br />

Technical Standards for Nuclear Reactor Facilities, and Article NCA‐4000 of<br />

ASME Sec.Ⅲ or KEPIC MNA) are satisfied.<br />

Whether the quality assurance program and technical specifications submitted by<br />

the reactor licensee as construction permit application documents are complied.<br />

Control of noncompliance and/or deficiencies found <strong>in</strong> the process of design and<br />

fabrication of major components are adequate.<br />

Control and evaluation of subcontracted items and services are adequately<br />

implemented.<br />

Whether contract conditions of major components presented by reactor licensee are<br />

met.<br />

Designer Inspection: Designer <strong>in</strong>spections are performed whenever new project starts<br />

and/or design related problems occur <strong>in</strong> fabrication, <strong>in</strong>stallation, and service of major<br />

❙ 462 ❙