1010 HOSTSRV OUTPUT HIC ANALYSIS ERROR<br />

Event 12 TCP–IP GATEWAY EVENT<br />

Description: The header received had an invalid HIC sequence. An error message is<br />

created and sent to the ULP. The host services module for the TCP–IP Stack program<br />

product generates this CENLOG.<br />

1011 HOSTSRV ERROR CODE FROM INCOMING MESSAGE<br />

Description: A message was received from the LLP with the message type of<br />

ERROR. The host services module for the TCP–IP Stack program product generates<br />

this CENLOG.<br />

1012 HOSTSRV NO SOURCE IP ADDRESS CONFIGURED<br />

Description: The TSID/PROCID combination was not found in the source address<br />

table; the search is done to obtain the source IP address. (The source address table is<br />

built from the HOSTID entries on the EU card.) This error causes the current session<br />

to terminate. The host services module for the TCP–IP Stack program product<br />

generates this CENLOG.<br />

1021 HOSTSRV UNEXPECTED DCA INPUT<br />

Description: A DCA control message was received that was not correct at this point<br />

of the processing sequence. The following information should be recorded and given<br />

to the site analyst:<br />

R12: Return address — contents of R7 before CENLOG call<br />

The host services module for the TCP–IP Stack program product generates this<br />

CENLOG.<br />

1022 HOSTSRV NO DCA$ ENTRY AVAILABLE<br />

Description: A new connection table entry could not be created either because the<br />

maximum number of TCP connections was reached or no segments were available for<br />

connection tables. The maximum number of TCP connections is a configurable value<br />

(TCPP). This condition is usually temporary. This error causes the current session to<br />

terminate. The host services module for the TCP–IP Stack program product generates<br />

this CENLOG.<br />

1023 HOSTSRV BAD DCA CC PACKET<br />

Description: A bad DCA connect confirm message was received. The host services<br />