Event 14 CONFIGURATION FILE ACCESS / REQUEST ERROR<br />

Event 14 CONFIGURATION FILE ACCESS / REQUEST<br />

ERROR<br />

CONFIGURATION ACCESS ERROR<br />

Description: This error message is the result of trying to access the configuration file<br />

and being unsuccessful.<br />

CONFIGURATION FILE ACCESS / REQUEST ERROR<br />

Description: Configuration file access error - cannot access incarnation number.<br />

<strong>Telcon</strong> generates this CENLOG.<br />

Action: If this event occurs frequently, retrieve the configuration file and start a<br />

batch run to activate the program.<br />

PDNMS<br />

Description: The X.25 PSCS NMS processing module (PDNMS) received an X.25<br />

PSCS specific NMS command, but X.25 PSCS is not initialized.<br />

Attributes affected: Configuration event. The X.25 PSCS program product<br />

generates this CENLOG. Procedure: PDNMS.<br />

Action: Verify that at least one of X.25 PSCS’s lines has been enabled on a valid line<br />

module using an NMS UP LINE command. If a line has already been enabled, then<br />

X.25 PSCS may currently be initializing, or an initialization error has occurred and has<br />

been recorded with a CENLOG class/event of 5/15 with a supplementary text message<br />

of: “PSCS initialization error.”<br />

PPID NOT FOUND<br />

RTC<br />

Description: During line termination (module PDNSVS) was unable to successfully<br />

access one of its link layer table (Z2$) entries. PDNSVS was unable to obtain a match<br />

based on the LINE STE index contained in the line control block (LCB).<br />

Attributes affected: Line event, Configuration event. The X.25 PSCS program<br />

product generates this CENLOG. Procedure: PDNSVS.<br />

Action: Online configuration changes to the LINE statement may require <strong>Telcon</strong> to<br />

be restarted. If this event occurs after <strong>Telcon</strong> is restarted, then a software error has<br />

either corrupted the LINE STE index in the PDNSVSs link- layer table or in the LCB.<br />

Description: A configuration error occurred while processing the ROUTE<br />

configuration statements. <strong>Telcon</strong> generates this CENLOG.<br />