SDLC (022): Stn config ERROR - Invalid Mode/Type Combo<br />

Event 11 ILM EVENT<br />

Description: An attempt was made to configure a station with an incompatible<br />

combination of Station Mode and Local Station Type. This CENLOG is generated by<br />

the SDLC link provider interface application (LPIA) for the ILM software.<br />

Action: Correct the configuration.<br />

Supplementary Data: Connection Control Block. For more information, refer to the<br />

ILM Platform Programming Reference <strong>Manual</strong> (7431 8569).<br />

SDLC (023): Stn config ERROR - Can't mix NRM Sec with anything<br />

Description: An attempt was made to configure an NRM secondary station on the<br />

same line as another station type. This CENLOG is generated by the SDLC link<br />

provider interface application (LPIA) for the ILM software.<br />

Action: Correct the configuration.<br />

Supplementary Data: Connection Control Block. For more information, refer to the<br />

ILM Platform Programming Reference <strong>Manual</strong> (7431 8569).<br />

SDLC (025): Data Set Ready (DSR) detected - LINE UP<br />

Description: Data Set Ready was detected on the line and the line was reported as<br />

up. This CENLOG is generated by the SDLC link provider interface application (LPIA)<br />

for the ILM software.<br />

Action: This is a normal occurrence that requires no user action.<br />

Supplementary Data: Line Control Block. For more information, refer to the ILM<br />

Platform Programming Reference <strong>Manual</strong> (7431 8569).<br />

SDLC (026): Data Set Ready (DSR) lost - LINE DOWN<br />

Description: Data-Set-Ready (DSR) was lost due to a line error or disconnection.<br />

This CENLOG is generated by the SDLC link provider interface application (LPIA) for<br />

the ILM software.<br />

Action: Automatic recovery should occur when the line connection is restored. If<br />

automatic recovery does not occur, try a DOWN of the line followed by an UP of the<br />

line from the NMS console.<br />

Supplementary Data: Line Control Block. For more information, refer to the ILM<br />

Platform Programming Reference <strong>Manual</strong> (7431 8569).<br />