Event 2 UNABLE TO RESTART PORT PROCESSOR<br />

Event 2 UNABLE TO RESTART PORT PROCESSOR<br />

UNABLE TO RESTART PORT PROCESSOR<br />

Description: The PORT PROCESSOR refers to one of the communication lines<br />

connected to the <strong>DCP</strong>. Refer to the port number associated with the CENLOG to<br />

isolate the inoperative line. The controlling CP procedure responsible for processing<br />

(due to an original error) caused the port to stop and caused the CENLOG. The<br />

original problem is visible through some other CENLOG display. <strong>Telcon</strong> generates<br />

this CENLOG.<br />

Action: Currently the port is not running. One action would be to DOWN and then<br />

UP the affected port using the appropriate NMS commands. If still not successful,<br />

notify someone knowledgeable about this communication line (problem may be<br />

hardware or software related).<br />

AGPPER<br />

Description: AGPPER was unable to restart the PP because of an error reported by<br />

LMLOAD.<br />

R8: Error bits returned from LMLOAD<br />

R9: IOPID<br />

R10: IOP table index<br />

R12: Microcode ID<br />

R13: Line module ID<br />

<strong>Telcon</strong> generates this CENLOG.<br />