X.25 Restart by <strong>DCP</strong>–“reason"<br />

Event 3 EVENT/ERROR DETECTED AT L3 (NETWORK)<br />

Description: The Common Network Management Service (CNMS) X.25 interface<br />

module in PDNSVS received an alarm notification. (CNMS does not need to be<br />

operating for this CENLOG to be enabled.) The layer 3 module sent a Restart packet<br />

to the network on a particular network connection (line). This event includes the<br />

LINE name.<br />

R8: PDNGRP STE index<br />

R10: Packet’s cause code. See Appendix C of this manual for a description of the<br />

cause code.<br />

R11: Packet’s diagnostic code. See Appendix A of this manual for a description of<br />

the diagnostic code.<br />

R12: CNMS alarm code<br />

Attributes affected: Supplementary text message, Line event, may include CNMS<br />

interface packet. The X.25 PSCS program product generates this CENLOG.<br />

Procedure: PDNSVS.<br />

X.25 Reset by Network–Cause,Diagnostic=hhhh,hhhh<br />

Description: The Common Network Management Service (CNMS) X.25 interface<br />

module in PDNSVS received an alarm notification. (CNMS does not need to be<br />

operating for this CENLOG to be enabled.) The layer 3 module received Reset packet<br />

from the network for a particular virtual circuit. This event includes the LINE name<br />

and may include the DTE statement name or address information.<br />

R8: PDNGRP STE index<br />

R9: Logical channel number<br />

R10: Packet’s cause code. See Appendix C of this manual for a description of the<br />

cause code.<br />

R11: Packet’s diagnostic code. See Appendix A of this manual for a description of<br />

the diagnostic code.<br />

R12: CNMS alarm code<br />

R13: Layer 4 routing identifier<br />

Attributes affected: Supplementary text message, Line event, Device event (if the<br />

clear [reset] packet is associated with a configured DTE statement and CNMS is not<br />

active), can include CNMS interface packet. The X.25 PSCS program product<br />

generates this CENLOG. Procedure: PDNSVS.<br />

7436 0728–303 13–67