Event 5 DYNAMIC SYSTEM SEGMENT ERROR<br />

SNA: 1407 – Could not enter segment into PST (err %%%%)<br />

SRC<br />

Description: This message occurs as a result of errors in SNMS, the part of SNA/net<br />

that processes operator commands. The % represents a hexadecimal number. The<br />

probable cause is a software problem.<br />

Description: SRC has encountered an invalid DSSN in AZ$LCKB while attempting to<br />

activate/deactivate a line during a resilient switch. <strong>Telcon</strong> generates this CENLOG.<br />

SYSTEM SEGMENT ERROR<br />

TRS<br />

Description: Various internal processes allocate space dynamically at runtime to<br />

contain various runtime tables. If an error is detected during the creation/usage of<br />

these segments, the calling procedure registers this statistic log entry. <strong>Telcon</strong><br />

generates this CENLOG.<br />

Action: Submit a UCF.<br />

Description: When TRS deallocates resources for the last terminal on a line, it calls<br />

the supervisor to delete the DSSN segment. If the use count is nonzero, it returns a<br />

status, indicating that the DSSN has not been deleted. TRS logs the error and gives up<br />

control. If this occurs, a process has most likely not cleared the PST entry.<br />

R11: LCB<br />

<strong>Telcon</strong> generates this CENLOG.<br />

TSTN<br />

Description: At TS/TN initialization, the DSSN number is loaded and an invalid DSSN<br />

number is specified by this CENLOG. <strong>Telcon</strong> generates this CENLOG.<br />