Sense Data<br />

D–10<br />

0819 RTR Not Required. Receiver of Ready to Receive has nothing to send.<br />

081A Request Sequence Error. Invalid sequence of requests.<br />

081B Receiver in Transmit Mode. A race condition exists: a normal-flow request was<br />

received while the half-duplex contention state was not-receive, (*S, ¬R), or<br />

while resources (such as buffers) necessary for handling normal-flow data<br />

were unavailable. (Contrast this sense code with X'2004', which signals a<br />

protocol violation.)<br />

081C Request Not Executable. The requested function cannot be executed because<br />

of a permanent error condition in the receiver.<br />

081D Invalid Station/SSCP ID. The station ID or SSCP ID in the request was found to<br />

be invalid.<br />

081E Session Reference Error. The request contained reference to a half-session<br />

that either could not be found or was not in the expected state (generally<br />

applies to network services requests).<br />

081F Reserved.<br />

0820 Control Vector Error. Invalid data for the control vector specified by the target<br />

network address and key.<br />

0821 Invalid Session Parameters. Session parameters were not valid or not<br />

supported by the half-session whose activation was requested.<br />

0822 Link Procedure Failure. A link-level procedure has failed due to link equipment<br />

failure, loss of contact with a link station, or an invalid response to a LINK<br />

command. (This is not a path error because the request being rejected was<br />

delivered to its destination.)<br />

0823 Unknown Control Vector. The control vector specified by a network address<br />

and key is not known to the receiver.<br />

0824 Logical Unit of Work Aborted. The current unit of work has been aborted;<br />

when sync point protocols are in use, both sync point managers are to revert to<br />

the previously committed sync point.<br />

0825 Component Not Available. The LU component (a device indicated by an FM<br />

header) is not available.<br />

0826 FM function not supported. A function requested in an FMD RU is not<br />

supported by the receiver.<br />

0827 Intermittent Error — Retry Requested. An error at the receiver caused an RU<br />

to be lost. The error is not permanent. Retry or the RU (or chain) is requested.<br />

0828 Reply Not Allowed. A request requires a normal-flow reply, but the outbound<br />

data flow for this half-session is quiesced or shut down. There is no delayed<br />

reply capability.<br />

7436 0728–303