ENET (025): Loopback output frame too short<br />

Event 11 ILM EVENT<br />

Description: The length of a diagnostic loopback (LOOP command) frame is less<br />

than the required addressing header. The loopback test failed. A long CENLOG<br />

shows the <strong>Telcon</strong> buffer header. The Ethernet link provider interface application<br />

(LPIA) for the ILM software generates this CENLOG.<br />

ENET (026): No LSAP for HLE/Facility ID<br />

Description: Configuration or software error. Output for this HLE/Facility ID is<br />

discarded. A long CENLOG shows the <strong>Telcon</strong> buffer header containing the offending<br />

HLE/Facility ID. The Ethernet link provider interface application (LPIA) for the ILM<br />

software generates this CENLOG.<br />

ENET (027): HLE output - not MAC or LLC (config error)<br />

Description: The SAP configuration ILMIF is not one of the permitted types: LLC<br />

Type 1, LLC Type 2, Transparent, or MAC. Output frames are discarded. A long<br />

CENLOG shows the output buffer. The Ethernet link provider interface application<br />

(LPIA) for the ILM software generates this CENLOG.<br />

Action: Correct the configuration.<br />

ENET (028): Can't connect MAC station to LAN (FATAL!)<br />

Description: LCC hardware, bulkhead connector or transceiver problem.<br />

Subsequent CENLOG(s) indicate the precise failure cause. ILM is not usable. The<br />

Ethernet link provider interface application (LPIA) for the ILM software generates this<br />

CENLOG.<br />

ENET (029): LCC H/W passed diagnostic self tests<br />

Description: ILM is operational on the 802.3 LAN. The Ethernet link provider<br />

interface application (LPIA) for the ILM software generates this CENLOG.<br />

ENET (030): LCC H/W failed diagnostic self tests (FATAL!)<br />

Description: INTEL 825x6 internal failure. ILM is not usable. The Ethernet link<br />

provider interface application (LPIA) for the ILM software generates this CENLOG.<br />

ENET (031): LCC H/W failed internal loopback (FATAL!)<br />

Description: INTEL 825x6 internal failure. ILM is not usable. The Ethernet link<br />

provider interface application (LPIA) for the ILM software generates this CENLOG.<br />