Event 1 HARDWARE LINE ERROR (NOT A PP STATE ITEM)<br />

UNISCOPE MESSAGE ERROR (PARITY ERROR)<br />

Description: VRC or LRC (parity check) error is detected. Can be caused by faulty<br />

line hardware, terminal hardware, or intolerable electrical noise on the line. R8<br />

contains 0100 or 0101 (bit 8 is set). UNILPH generates this CENLOG. For more<br />

information on UNILPH CENLOG entry descriptions, refer to Section 1 of this manual.<br />

Action: If this error occurs for many terminals on the same line, check and repair the<br />

line hardware and its electrical environment (including cables, modems, DCMs, and<br />

multiplexers).<br />

If this error occurs for only one terminal, or only for terminals connected to the same<br />

cluster controller, check and repair the terminal or cluster.<br />

If this error occurs often enough to cause undue overhead to the system, you can<br />

issue an NMS STOP command for the line, poll group, or terminal, as applicable.<br />

When the offending hardware has been fixed or taken offline, issue an NMS STRT<br />

command to restore a normal operating environment.<br />

UNISCOPE PORT PROCESSOR ERROR (HUNG PP)<br />

Description: Port processor error (hung IOP). This error is detected when the LPH<br />

has requested a response from the IOP and the IOP fails to respond within a<br />

reasonable amount of time. This condition generally occurs when the line module<br />

hangs or is faulty. When this condition is discovered, the LPH forces a state item to<br />

get to a known state on that port. At that point, system state processing is invoked<br />

(see PP STATE ITEM error description). R8 contains the value 00E8. <strong>Telcon</strong><br />

generates this CENLOG.<br />

Action: Wait for state-item processing to be completed and reported, and proceed<br />

accordingly (see description for PP STATE ITEM RECEIVED).<br />

15–4 7436 0728–303