Event 11 ILM EVENT<br />

SDLC (043): Max XID commands sent without valid response<br />

Description: The maximum number of XID commands was sent without receiving a<br />

valid reply. This CENLOG is generated by the SDLC link provider interface<br />

application (LPIA) for the ILM software.<br />

Action: Check the configuration and the connection.<br />

SDLC (050): FRMR sent,...<br />

Description: A frame reject response was sent. The control frame of the rejected<br />

command, the expected N(s) and N(r), and the reason code for the frame reject are<br />

also displayed.<br />

Action: None.<br />

SNAUIA0 (001): Snau_main: SNAUIA Registered with Platform<br />

Description: The SNA User Interface application registered itself with the data link<br />

controller manager (DLCMAN).<br />

SNAUIA0 (024): fwdSaiChg: Send to HLE failed<br />

Description: An error occurred which prevents the SNA User Interface application<br />

from sending control messages to the High Level Entity (HLE).<br />

SNAUIA0 (031): No free Connection<br />

Description: The SNA user interface application has exceeded the maximum<br />

number of PU(s).<br />

SNAUIA0 (032): No segment available for PU_alloc request<br />

Description: The SNA user interface application has no memory available for the<br />

PU.<br />

SNAUIA0 (047): SnaulnvState: Invalid state for message received<br />

Description: The SNA User Interface application received a message while the<br />

connection was not in receive mode.<br />

SNAUIA0 (066): PU role mismatch<br />

Description: The SNA user interface application has detected a configuration error.<br />

When LSTYP=NEG (negotiable) only one PU can be configured/active on the line.<br />

When configuring multiple PU(s) on a line, all the PU(s) must be configured with the<br />

same LSTYP parameter which can be either PRIM or SEC.<br />