Event 12 TCP–IP GATEWAY EVENT<br />

IP: OUTPUT LOST, QUEUE FULL<br />

Description: DNS, host channel (HCC), LAN, or PSCS is not keeping up with IP or<br />

other users of DNS. IP detected an internal error. This could indicate a serious<br />

software fault. The TCP–IP Stack program product generates this CENLOG.<br />

IP: REJECT CALL, NO RESOURCES<br />

Description: A PSCS call was rejected because of a lack of resources. If this event<br />

occurs frequently, recheck your sizing requirements. The TCP–IP Stack program<br />

product generates this CENLOG.<br />

IP: SET TIMER FAILED<br />

Description: IP had to drop a heartbeat timer used to check on virtual activity, due<br />

to a lack of resources. This means that IP will no longer disconnect X.25 SVCs when<br />

they become inactive. This is not a serious problem unless hosts on the LAN change<br />

their addresses. The TCP–IP Stack program product generates this CENLOG.<br />

Action: Although this problem is not serious, the only recourse is to restart <strong>Telcon</strong>.<br />

If this event occurs frequently, recheck your sizing requirements.<br />

IP: SET TIMER FAILED FOR ADR - !<br />

Description: TCP–IP Stack detected an internal error. This condition is normally<br />

recoverable. The TCP–IP Stack program product generates this CENLOG.<br />

Action: If this condition persists, contact your support center.<br />

IP: STACK CORRUPTED<br />

Description: IP detected an internal error. This could indicate a serious software<br />

fault. The TCP–IP Stack program product generates this CENLOG.<br />

IP: STRICT SOURCE ROUTE FAILED<br />

Description: TCP–IP could not forward a message with a strict source route option.<br />

The rules for processing a strict source route option do not permit forwarding this<br />

message. This condition is normally not recoverable. The TCP–IP Stack program<br />

product generates this CENLOG.<br />

Action: If this condition persists, contact your support center.<br />

IP: SUBNET/IPADR HAVE SAME ADR = nnn.nnn.nnn.nnn<br />

Description: Configuration error. Cannot specify a local IP address with the nonnetwork<br />

portion all zeros.<br />