RIP: No IPNETID found for net # of IPGATEWY<br />

Event 12 TCP–IP GATEWAY EVENT<br />

Description: TCP–IP Stack detected a configuration error. The IPGATEWY<br />

parameter of a SUBNET statement specifies an IP address for which there is no<br />

configured interface. The TCP–IP Stack program product generates this CENLOG.<br />

Action: Verify the configuration to make sure all IP addresses are specified correctly.<br />

RIP: No space for new route<br />

Description: TCP–IP Stack was not able to get needed memory resources. Some<br />

routes may not be available. The TCP–IP Stack program product generates this<br />

CENLOG.<br />

RIP: RIP on but no LINE specified<br />

Description: TCP–IP Stack detected a configuration error. A SUBNET statement<br />

specifies RIP=YES, but does not specify an interface. The TCP–IP Stack program<br />

product generates this CENLOG.<br />

Action: Either remove the RIP parameter, or add a LINE, CHANNEL, or PDNGRP<br />

parameter.<br />

RIP: RIP on but IP Routing is off<br />

Description: TCP–IP Stack detected a configuration error. A SUBNET statement<br />

specified RIP=YES, but does not specify IPROUTER=YES. Some configured<br />

functions may not be available. The TCP–IP Stack program product generates this<br />

CENLOG.<br />

Action: Either set RIP=SILENT or add IPROUTER=YES.<br />

RIP: RIP not supported on SUBNET TYPE<br />

Description: TCP–IP Stack detected a configuration error (DDN, IPCHAN, or<br />

IPPDN). A SUBNET statement specifies RIP=YES, but the TYPE parameter indicates<br />

an incompatible value. The TCP–IP Stack program product generates this CENLOG.<br />

Action: Remove the RIP parameter. Verify that the correct TYPE parameter was<br />

used.<br />

RIP: Route table allocation failure<br />

Description: RIP cannot acquire enough memory for its routing table. The routing<br />

information protocol module for the TCP–IP Stack program product generates this<br />

CENLOG.<br />