Event 2 COMMUNICATIONS LINE PROTOCOL ERROR DETECTED<br />

REPLY REQUEST ERROR (UNISCOPE)<br />

Description: This is a recoverable line protocol error that is generally caused by<br />

faulty line or terminal hardware, or unacceptable electrical noise on the line. R8<br />

contains the value 00E6. UNILPH generates this CENLOG. For more information on<br />

UNILPH CENLOG entry descriptions, refer to Section 1 of this manual.<br />

Action: If this error occurs for many terminals on the same line, check and repair the<br />

line hardware and its electrical environment (including cables, modems, DCMs,<br />

multiplexers).<br />

If this error occurs for only one terminal, or only for terminals connected to the same<br />

cluster controller, check and repair the terminal or cluster.<br />

If this error occurs often enough to cause undue overhead to the system, issue an<br />

NMS STOP command for the line, poll group, or terminal as applicable. When the<br />

malfunctioning hardware has been taken offline, issue an NMS STRT command to<br />

restore a normal operating environment.<br />

RMLPH<br />

Description: I/O failure due to hardware detected error.<br />

R15: IOP ID<br />

<strong>Telcon</strong> generates this CENLOG.<br />

RMLPH<br />

Description: The terminal has sent a retransmit character and the data buffer should<br />

be retransmitted.<br />

R14: IOP ID<br />

<strong>Telcon</strong> generates this CENLOG.<br />

UDLCRS<br />

Description: An F bit was received even though a P bit was not out. The input frame<br />

is ignored, R8 = 001D. <strong>Telcon</strong> generates this CENLOG.<br />

UDLCRS<br />

Description: A non-XID frame was received during the XID exchange phase of UDLC<br />

line connection. The frame is discarded–an XID frame is still expected, R8 = 003E.<br />

<strong>Telcon</strong> generates this CENLOG.<br />