Event 3 EVENT/ERROR DETECTED AT L3 (NETWORK)<br />

X.25 Restart by Network – Cause,Diagnostic=hhhh,hhhh<br />

Description: The Common Network Management Service (CNMS) X.25 interface<br />

module in PDNSVS received an alarm notification. (CNMS does not need to be<br />

operating for this CENLOG to be enabled.) The layer 3 module received a restart<br />

packet from the network on a particular network connection (line). This event<br />

includes the LINE name.<br />

R8: PDNGRP STE index<br />

R10: Packet’s cause code. See Appendix C of this manual for a description of the<br />

cause code.<br />

R11: Packet’s diagnostic code. See Appendix A of this manual for a description of<br />

the diagnostic code.<br />

R12: CNMS alarm code<br />

Attributes affected: Supplementary text message, Line event, may include CNMS<br />

interface packet. The X.25 PSCS program product generates this CENLOG.<br />

Procedure: PDNSVS.<br />

X.25 SNMP: ICS Registration Failed (“procedure name”)<br />

Description: The X.25 PSCS SNMP interface module (PDNSMP) received an ICS<br />

Registration Response message with an error code. This error causes PDNSMP to<br />

become dormant. In this case, no SNMP MIB information related to X.25 can be<br />

retrieved.<br />

R8: ICS Registration Response error code<br />

Attributes affected: Error event, supplementary text message, and a table of the ICS<br />

response packet.<br />

Action: This event indicates an internal software interface error. Submit the contents<br />

of the entry to your <strong>Unisys</strong> representative for analysis. You must re-start your <strong>Telcon</strong><br />

run, and you may need to re-start ICS, in order to recover from this error. If the error<br />

re-occurs, take a <strong>Telcon</strong> dump and submit a UCF.<br />

Procedure: The procedure name, which is internal to the X.25 PSCS PDNSMP<br />

module, is displayed as part of the supplementary text message.<br />

13–68 7436 0728–303