Event 8 LINE DISCONNECTION COMPLETED<br />

Event 8 LINE DISCONNECTION COMPLETED<br />

LINE DISCONNECTION COMPLETED<br />

Description: The physical line has been disconnected from the <strong>DCP</strong> and the line<br />

resources deallocated. <strong>Telcon</strong> generates this CENLOG.<br />

Action: None.<br />

BSC LPH<br />

Description: Generated when the BSC LPH receives a status from the IOP indicating<br />

loss of data-set-ready. This causes the BSC site to be terminated.<br />

R8: The flag word for the BSC LPH. The exact meaning of each bit can be found<br />

in the assembly of AAHARDEF. It contains flags indicating message transfer<br />

state, I/O direction, site termination, and so on.<br />

R9: Contains the IOP status word. The exact definition can be found in the<br />

assembly of AAHARDEF.<br />

R11: The address of the LCB<br />

R12: The address of the TCB<br />

R14: The IOP ID<br />

LMS<br />

<strong>Telcon</strong> generates this CENLOG.<br />

Description: LMS was notified by the link of a line disconnection. <strong>Telcon</strong> generates<br />

this CENLOG.<br />

PDNSVS<br />

Description: The Common Network Management Service (CNMS) X.25 interface<br />

module in PDNSVS received an NMS DOWN LINE indication. This event includes the<br />

LINE name.<br />

R10: PDNGRP STE index<br />

Attributes affected: Line event, Line Control Block (LCB) address may be in<br />

Register R11. The X.25 PSCS program product generates this CENLOG.<br />

Procedure: PDNSVS<br />