IP: CLEAR COLLISION: CAUSE = #, DIAG = #<br />

Event 12 TCP–IP GATEWAY EVENT<br />

Description: IP received a clear indication on a virtual circuit that was expecting a<br />

clear confirmation. The TCP–IP program product generates this CENLOG.<br />

IP: CONFIG ACCESS ERR: DLCUNIT PROCESSING<br />

Description: IP cannot read a DLCUNIT configuration statement. IP detected an<br />

internal error. This may indicate a serious software fault. The TCP–IP Stack program<br />

product generates this CENLOG.<br />

IP: CONFIG ACCESS ERR IN SAP PROCESSING<br />

Description: IP cannot read a SAP configuration statement. IP detected an internal<br />

error. This may indicate a serious software fault. The TCP–IP Stack program product<br />

generates this CENLOG.<br />

IP: CONFIG CONFLICT LOCAL ADDRESS = !<br />

Description: A configuration error was detected. The IPADR statement specifying<br />

the indicated IP address may be in error. There is no matching IP address in the ENS<br />

IP Router configuration. Some configuration functions may not be available. The<br />

TCP–IP Stack program product generates this CENLOG.<br />

IP: CONFIGURATION ERROR,<br />

RESTART TELCON FOR ONLINE CONFIGURATION CHANGES<br />

Description: IP detected configuration errors. Internal tables do not match<br />

configuration information. This error can occur when online configuration changes<br />

are made. The<br />

TCP–IP Stack program product generates this CENLOG.<br />

IP: DGSIZE REDUCED FROM n TO n BYTES BY LINE linename<br />

Description: Possible configuration error. Compare datagram size in SUBNET<br />

statement with maximum datagram size permitted by line module.<br />

IP: DIFFERENT SUBNET TYPES W/SAME NET: !<br />

Description: IP found more than one SUBNET configuration, each with a different<br />

TYPE parameter. The TCP–IP Stack program product generates this CENLOG.<br />

IP: DLCUNIT CONFIG ERROR: STE = #<br />

Description: DLCUNIT facility identifier is invalid. This error can occur when online<br />

configuration changes are made. The TCP–IP Stack program product generates this<br />

CENLOG.<br />