Event 11 ILM EVENT<br />

LMMGT (039): Detach request timed out<br />

Description: An IA took more than 5 seconds to respond to a request. The Platform<br />

takes the action to respond. This CENLOG is generated by the line module’s ILM<br />

Platform manager.<br />

LMMGT (040): Invalid packet received from IA on ILMSVC call<br />

Description: An IA attempted to pass a packet to the ILM Platform by means of an<br />

ILMSVC call. The packet type was not recognized by the manager. (IA software<br />

error.) This CENLOG is generated by the line module’s ILM Platform manager.<br />

LMMGT (041): All lines are already active<br />

Description: A build LCB call was made to the ILM Platform manager when all lines<br />

are already assigned. This CENLOG is generated by the line module’s ILM Platform<br />

manager.<br />

LMMGT (042): Requested line number out of range<br />

Description: A build LCB call was made to the ILM Platform manager with an invalid<br />

line number. This CENLOG is generated by the line module’s ILM Platform manager.<br />

LMMGT (043): LCB already allocated<br />

Description: A build LCB call was made to the ILM Platform manager for a line that<br />

is already busy. This CENLOG is generated by the line module’s ILM Platform<br />

manager.<br />

LMMGT (044): LCB offspring still linked to LCB<br />

Description: A call was made to the ILM Platform manager to delete an LCB. The<br />

LCB still has subordinate facilities linked to it. This CENLOG is generated by the line<br />

module’s ILM Platform manager.<br />

LMMGT (045): 'Alloc_msg' failed, trace buffer lost<br />

Description: The ILM Platform manager is unable to allocate a trace buffer. Traces<br />

are lost. This CENLOG is generated by the line module’s ILM Platform manager.<br />

PPP (nnn) Registration with DLCMAN complete<br />

Description: PPP has registered with DLCMAN (nnn is an indicator of the location of<br />

the CENLOG in the PPP software).<br />

Action: None.<br />

6–82 7436 0728–303