Event 4 PORT PROCESSOR (PP) SPECIFICATION EXCEPTION<br />

TTYLPH<br />

Description: This event occurs if a fatal hardware or software error occurs on the<br />

PP being used. This results in all lines configured on the PP being downed. Other<br />

information logged:<br />

R9: State-item error type<br />

R10: State-item error sub-type<br />

R12: Output chain execution address<br />

R13: Input chain execution address<br />

R14: PPID (no 4X1 line # present). The PP state-item buffer (64 words) structured,<br />

as stated in the preface of the <strong>DCP</strong>/40 System Description. The contents of<br />

the PP fixed-space for the PP program used (as defined in location counter 0<br />

of TTYIOP for 4X1 line modules, and location counter 0 of TTYLPH for 1X1<br />

line modules).<br />

<strong>Telcon</strong> generates this CENLOG.<br />

7–8 7436 0728–303