Event 15 CONFIGURATION ERROR DETECTED / UNDEFINED<br />

OSIIP–SUBNET SPACE FULL<br />

Description: The maximum number of OSISN configuration statements has been<br />

exceeded. The OSIIP component of the OSITS program product generates this<br />

CENLOG.<br />

Reason: Configuration error.<br />

OSIIP–UNRECOGNIZED NDS<br />

Description: An attempt was made to process an NDS (configuration statement)<br />

type other than an NSAP, OSIROUTE, or OSISN. The OSIIP component of the OSITS<br />

program product generates this CENLOG.<br />

Reason: Configuration error.<br />

OSIIP–UNRECOGNIZED PSCS FUNCTION CODE<br />

Description: An attempt was made to process a configuration statement type other<br />

than an NSAP, OSIROUTE, or OSISN. The OSIIP component of the OSITS program<br />

product generates this CENLOG.<br />

Reason: Program product mismatch.<br />

OSIIP–STATIC CIRCUIT IGNORED<br />

Description: Request to build static circuit subnet received after system has<br />

initialized. The OSIIP component of the OSITS program product generates this<br />

CENLOG.<br />

Reason: Configuration request in error.<br />

OSIIP–SPECIFIC NSAP CONFLICT<br />

Description: Multiple NSAP configuration statements reference the same<br />

subnetwork by way of an OSISN keyword. The OSIIP component of the OSITS<br />

program product generates this CENLOG.<br />

Reason: Configuration request in error.<br />