Event 6 INVALID COMMAND / CONTROL / HIC RECEIVED<br />

DMOPEN<br />

DTP<br />

Description: When an ATTACH request is rejected by DMOPEN, an ATTACH reject<br />

is generated and returned to DTPX. DMOPEN sends the reject request to DTPX using<br />

a call to CSUAFI, which requires data on CSU class and CSU ID. This code is used<br />

when DMOPEN fails to find a valid CSU class or CSU and the ATTACH request is<br />

thrown away.<br />

R8: CSU ID<br />

R9: CSU ID<br />

R10: ATTACH request buffer address<br />

<strong>Telcon</strong> generates this CENLOG.<br />

Description: DTP has received an unrecognizable control message. One of the<br />

following conditions has occurred: The byte count = 0. The control message<br />

identification HIC (first HIC) is not valid (is not recognized by DTP). A flow control<br />

HIC (X'03') has been received from the transport service user, but the variant is<br />

neither “start” nor “stop.” <strong>Telcon</strong> generates this CENLOG.<br />

DTVTR<br />

Description: The DCT 1000 VTR received an HIC that is unrecognizable and invalid.<br />

R12: TCB address<br />

R14: PPID<br />

R15: RID/SID<br />

<strong>Telcon</strong> generates this CENLOG.<br />

INVALID COMMAND / CONTROL/ HIC RECEIVED<br />

Description: This message indicates that a procedure received a control message<br />

that contains invalid data. <strong>Telcon</strong> generates this CENLOG.<br />

Action: Submit a UCF.<br />