Event 11 ILM EVENT<br />

LAPBHS (045): OLD station configuration OVER-WRITTEN by NEW<br />

Description: There is more than one station configured for a line. Only the last<br />

station configuration packet is honored. This CENLOG also can indicate a second<br />

attempt to bring up a station.<br />

Action: Check the <strong>Telcon</strong> configuration and correct if necessary.<br />

LAPBHS (046): Output message of invalid length Discarded<br />

Description: There was an output attempt of a message larger than the configured<br />

maximum I-frame size. The message was discarded.<br />

Action: Correct the <strong>Telcon</strong> configuration.<br />

LAPBHS (047): Up Station FAILED - no UDM queue<br />

Description: This is a software error.<br />

Action: Contact your <strong>Unisys</strong> representative.<br />

LAPBHS (048): Up Station FAILED - no input data queue<br />

Description: This is a software error.<br />

Action: Contact your <strong>Unisys</strong> representative.<br />

LAPBHS (049): Indication packet REJECTED by ILM platform<br />

Description: This is a software error.<br />

Action: Contact your <strong>Unisys</strong> representative.<br />

LAPBHS (050): Return of ATTACH/DETACH packet rejected<br />

Description: This is a software error.<br />

Action: Contact your <strong>Unisys</strong> representative.<br />

LAPBHS (051): XPC driver error - illegal command<br />

Description: This is a software error. The hardware driver issued an invalid<br />

command or a valid command at a time when that command is not allowed.<br />

Action: The software will attempt recovery. An ILM DUMP may indicate the cause<br />

of the failure. Contact your <strong>Unisys</strong> representative.<br />