NMS and DSA <strong>Message</strong>s<br />

*** ERROR: DTYP VALUE INVALID ***<br />

Description: The parameter value can be only one of a few fixed-character strings<br />

(names).<br />

Action: Change the value, and reenter the command.<br />

*** ERROR: DUPLICATE FACILITY NAME ***<br />

Description: This is the response to the MOVE command when the facility being<br />

moved already exists on the destination <strong>Telcon</strong> node.<br />

Action: Verify the facility name, and reenter the MOVE command.<br />

*** ERROR: DUPLICATE FILE NAME ***<br />

Description: The specified file is already cataloged.<br />

Action: Change the file name, and reenter the command.<br />

*** ERROR: EXTERNAL COMMAND TEXT MISSING ***<br />

Description: The XCMD must be followed by a non-blank character string.<br />

Action: Verify the text, and reenter the command.<br />

*** ERROR: FACILITY NOT FOUND ***<br />

Description: The facility name is not defined according to the following:<br />

• Configuration<br />

• Directory services<br />

• Directory services is not available<br />

Action:<br />

• Verify the facility name.<br />

• If using directory services, verify that the DSA is running.<br />

*** ERROR: FACILITY MUST BE A TERM-LINE OR CLTR OR TERM ***<br />

Description: The LINE, CLTR, TERM, or STN facility specified on the MOVE<br />

command is not a terminal line, cluster, terminal, or station.<br />

Action: Verify the facility type and name, and reenter the MOVE command.<br />